# BT APP configuration file # Enable BT On by default # valid value : true, false BtEnableByDefault=false # Local device BT name BtLocalDeviceName=MDM_Fluoride # User Interface is needed # valid value : true, false UserInteractionNeeded=true # socket handler # valid value : true, false BtSockInputEnabled=true # Enable Pan by default # valid value : true, false BtPanEnable=true # NAP role Support # valid value : true, false BtPanNapRoleSupported=true # PANU role Support # valid value : true, false BtPanPanuRoleSupported=true # Enable GATT by default # valid value : true, false BtGattEnable=true # Enable OBEX by default # valid value : true, false BtObexEnable=true # OBEX logging levels # valid value: 1-6 # 0 - Application output # 1 - Error message output # 2 - Warning message output # 3 - User API function trace output # 4 - Catagory 1 debug print output # 5 - Catagory 2 debug print output # 6 - Error/Debug output header BtObexLogLevel=3 # Enable Pbap Client by default # valid value : true, false BtPbapClientEnable=true # Enable OPP Client & Server by default # valid value : true, false BtOppEnable=true # Enable BLE Supported Profiles # valid value : Even Bits per profile # REMOTE_START_PROFILE (0x01) # ALERT_NOTIFICATION_PROFILE (0x02) # CYCLING_SPEED__cADENCE_PROFILE (0x04) # CYCLING_POWER_PROFILE (0x08) # RUNNING_SPEED_CADENCE_PROFILE (0x10) # HUMAN_INTERFACE_DEVICE_PROFILE (0x20) # HEART_RATE_PROFILE (0x40) BtBleSupportedProfiles=0x01 # Scan Mode Configuration # valid value : 0, 1 and 2 # BT_SCAN_MODE_NONE =0, # BT_SCAN_MODE_CONNECTABLE =1, # BT_SCAN_MODE_CONNECTABLE_DISCOVERABLE =2 BtScanMode=2 # A2DP Sink Enable # valid value : true, false BtA2dpSinkEnable=true # AVRCP Enable # valid value : true, false BtAvrcpEnable=true # HFP client Enable # valid value : true, false BtHfClientEnable=true # HFP AG Enable # valid value : true, false # AG and HFP client are mutually exclusive. Enable only one at a time BtHfpAGEnable=false # A2DP Source Enable # valid value : true, false BtA2dpSourceEnable=false # Use A2DP HAL for A2DP Sink # valid value : true, false BtUseA2dpHalForSink=false # Fetch RTP info for A2DP Sink # valid value : true, false BtFetchRTPForSink=false # Max a2dp sink and avrcp ct connections # valid value : 1 and 2 BtMaxA2dpConn=1 # Relay data from src to sink # valid value : true, false BtRelaySinkDatatoSrc=false # Enable Callback mechanism to notify BTAPP # about incoming media data in fluoride stack # valid value: true or false BtMediaNotificationCb=false